Bunn dual sh dbc Servisní příručka Strana 31

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 34
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 30
Page 31
If continuity is present as described, reconnect the
wires, the tank heaters are operating properly.
If continuity is not present as described, replace the
tank heater(s).
NOTE - If the tank heater remains unable to heat,
remove and inspect the heater for cracks in the sheath.
Removal and Replacement:
1. Remove wires from tank heater.
2. Remove the four #8-32 nuts securing tank heater
to tank lid.
3. Remove tank heater and gasket.
4. Install new tank heater and gasket with four #8-32
nuts on tank lid.
5. Refer to Fig. 34 when reconnecting the wires.
SERVICE (cont.)
TANK HEATERS
P803
Location:
The tank heaters are located on the left and right
side of the tank lid.
Test Procedure:
1. Disconnect the brewer from the power supply.
2 Check the voltage across the black and the blue
wires on the tank heaters. With the control ther-
mostat turned to the "ON" position (fully clock-
wise), connect the brewer to the power supply and
check the voltage across the wires with a voltme-
ter. The indication should be 208 volts ac for three
wire 120/208 volt models and 240 volts ac for
three wire 120/240 volt models.
3. Disconnect the brewer from the power supply.
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to the
wiring diagrams and check the wiring harness.
4. Remove the black and blue wires from the tank
heaters.
5. Check for continuity across the terminals of the
tank heaters.
FIG. 33 TANK HEATERS
P2232
FIG. 34 TANK HEATER TERMINALS
32248 100500
LEFT & RIGHT
BLK to Limit Thermostat
BLU to Triac
Zobrazit stránku 30