Bunn G9-2T DBC Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Nástroje Bunn G9-2T DBC. Bunn G9-2T DBC User Manual [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 79
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
GRINDERS
Includes: MHG, FPG,
FPG-2, LPG-2, G1, G2, G3,
G2 trifecta™, G9, G9WD,
G9-2 & G9-2T DBC
SERVICE & REPAIR MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
To ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts
Catalog, Programming Manual, or Service Manual, please visit the Bunn-O-Matic website, at
www.bunn.com. This is absolutely FREE, and the quickest way to obtain the latest catalog and
manual updates. For Technical Service, contact Bunn-O-Matic Corporation at 1-800-286-6070.
41545.0000C 11/11 ©2009 Bunn-O-Matic Corporation
Zobrazit stránku 0
1 2 3 4 5 6 ... 78 79

Shrnutí obsahu

Strany 1 - GRINDERS

GRINDERSIncludes: MHG, FPG,FPG-2, LPG-2, G1, G2, G3,G2 trifecta™, G9, G9WD,G9-2 & G9-2T DBCSERVICE & REPAIR MANUALBUNN-O-MATIC CORPORATIONPOST

Strany 2 - 41545 092611

10TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the proble

Strany 3 - 41545 111711

11TROUBLESHOOTING (cont.)ProblemProbable CauseRemedyEach motor is equipped with a temperature and current overload protection feature which will im-me

Strany 4 - 41545 072710

12Begin each grind cycle by visually inspecting the hopper(s) for ample supplies of whole bean coffee.Foreign materials must not block the openings at

Strany 5 - WARNING

13PROBLEMPROBABLE CAUSEREMEDYTROUBLESHOOTING (cont.)Incorrect coffee grind dispensed.Excessive chaffGrinder only dispenses from one hopperTimer will n

Strany 6 - Model G9WD

14SERVICE This section provides procedures for testing and replacing various major components used in this grinder should service become necessary.

Strany 7 - Models LPG, LPG-2E

15SERVICE (Cont.)FIG. 1 BAG SENSOR SWITCHP1704Location:The bag sensor switch is located inside the lower front of the grinder housing behind the coffe

Strany 8 - Model MHG

16SERVICE (Cont.)AC MOTOR AND GRIND CHAMBERFIG. 3 AC MOTOR AND GRIND CHAMBERP1704Location: The motor is located inside the upper part of the grinder

Strany 9 - Model FPG-2 DBC

17SERVICE (Cont.)WHI/BLU toRelay N.O.(K4)WHI to Cordset (120V)RED/BLK to Cordset (230V)GRN to Ground (120V)GRN/YEL to Ground (230V)P1310FIG. 4 AC MOTO

Strany 10 - TROUBLESHOOTING

18SERVICE (Cont.)FIG. 5 GRIND CHAMBER COMPONENTSP170820 7 6 4 51618 1 19 1711 10 9 8 3 2 1137121415AC MOTOR AND GR

Strany 11 - TROUBLESHOOTING (cont.)

19SERVICE (Cont.)DC MOTOR AND GRIND CHAMBER - G1MD ONLY FIG. 6 DC MOTOR AND GRIND CHAMBERP1706Location:The motor is located inside the upper part of t

Strany 12 - 41545 122209

2BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTYBunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:1) All equipment other than as s

Strany 13

20SERVICE (Cont.)DC MOTOR AND GRIND CHAMBER - G1MD ONLY (cont.) BLU to BLU from Rectifier BLU to WHI/BLU fromRelay (3)RED to Rectifier (-)BLK to Rectifie

Strany 14 - Component Locations

21SERVICE (Cont.)DC MOTOR AND GRIND CHAMBER - G1MD ONLY (cont.) FIG. 8 MOTOR AND GRIND CHAMBER REMOVALP17115 7 61618 1 19 179

Strany 15 - SERVICE (Cont.)

22SERVICE (Cont.)P1022Location: The motor is located inside the hopper assembly.Test Procedures:1. Disconnect grinder from the power supply.2. On M

Strany 16

23SERVICE (Cont.)1. Retaining Ring W/Hopper Gasket2. Slide Plate, Solenoid Plunger and Spring3. Spacer Plate4. Mounting Ring, Solenoid and Solenoi

Strany 17

24SERVICE (Cont.)20. Remove the two #8-32 flat head screws securing the motor cover (18) to the motor and housing assembly (17) and remove the cover. S

Strany 18

25SERVICE (Cont.)DECHAFFER (Models LPG & FPG)FIG. 13 DECHAFFERP1062Location: The dechaffer spring plates are located in the burr housing cap. 1FI

Strany 19

26SERVICE (Cont.)2. The entire wiring harness must be fed into the bottom of the grinder housing through the hole in the motor mounting plate.3. Rem

Strany 20

2701234567891011121314151. Indicator Adjustment Cap & Decal2. Adjusting Screw3. Burr Housing Cap4. Rotor Cup5. Shear Plate9876543216. Rotor7.

Strany 21

28SERVICE (Cont.)SNUBBER (Models G9, G9-2, MHG)COARSE FINETHOROUGHLY CLEAN GRIND CHAMBER BEFORE REASSEMBLY EMPTY HOPPER BEFORE REMOVING THIS COVER

Strany 22

29CALIBRATION1. Place empty funnel into funnel rails.2. Press and hold the right hidden (copyright) button until the “MACHINE TYPE” menu appears. (S

Strany 23

3CONTENTSWarranty and Trademark ...3Introduction ...

Strany 24

30P1745FIG. 20 CAPACITORLocation: The capacitor is located inside the front panel of the hopper housing next to the Off/On/Start switch.Test Procedur

Strany 25

31SERVICE (Cont.)Circuit Breaker (Models LPG, LPG-2E, FPG, FPG-2 DBC)P1036FIG. 22 CIRCUIT BREAKERP1037FIG. 23 CIRCUIT BREAKER TERMINALSRED from Motor-

Strany 26

32SERVICE (Cont.)P1038Hopper Selector Switch (Model LPG-2E only)P1029Location: The Hopper Selector Switch is located in thelower left front of the ho

Strany 27

33SERVICE (Cont.)Hopper Selector Switch (Model G9-2 only)FIG. 26 HOPPER SELECTOR SWITCHP594Location: The hopper selector switch is located in the cen

Strany 28

34SERVICE (Cont.)Location: The Off/On/Start switch is located to the left side on the front of the housing above the upper front inspec-tion panel.T

Strany 29

35SERVICE (Cont.)URNOFFSTARTONCARAFEP1300Location: The Urn/Carafe switch is located to the left side on the front of the housing above the upper insp

Strany 30

36SERVICE (Cont.)FIG 32 BATCH SELECTOR SWITCHLocation: The batch selector switch is located on the left front of the hopper housing.Test Procedure:1.

Strany 31

37SMALL MEDIUM LARGEP2946SERVICE (Cont.)FIG 34 POTENTIOMETERSLocation: The potentiometer switches are located on the top rear of the hopper housing.T

Strany 32

38SERVICE (Cont.)+ACACRemoval and Replacement:1. Disconnect the wires from the rectifier.2. Remove the #10-32 screw securing the rectifier to the moto

Strany 33

39SERVICE (Cont.)Location:The relay is located on the timer bracket in the grinder base. The bracket can be removed by loosening the two 8-32 screws b

Strany 34

4INTRODUCTION The Grinder will store various amounts of whole bean coffee and grind it to a preset grind and amount into an awaiting funnel and filter

Strany 35

40SERVICE (Cont.)Location: The relay is located on the grinder base inside the lower housing.Test Procedure:1. Disconnect the grinder from the power

Strany 36

41SERVICE (Cont.)WHI/BLU fromMotor to Relay K-4WHI/ORN from Bag Sensor Switch (A)FIG. 41 RELAY TERMINALSP1707RELAY (cont.)WHI to MainHarness 120V (B)R

Strany 37

42SERVICE (Cont.)Location:The relay is located either on the timer bracket or on the component mounting bracket in the grinder base. The bracket can b

Strany 38

43SERVICE (Cont.)Location: The slide plates are located on the solenoid mount-ing plate immediately beneath the hopper openings. The slide plates mu

Strany 39

44SERVICE (Cont.)Location: The slide plates are located on the solenoid mount-ing plate immediately beneath the hopper openings. The slide plates mu

Strany 40

45SERVICE (Cont.)LeftRightWHI/ORN to Timer P4-4RED/BLK to Right SolenoidRED/BLK to Timer P4-7WHI/YEL to Timer P4-5RED/BLK to Left SolenoidP612Location

Strany 41

46SERVICE (Cont.)Timer (Model LPG-2E)P1061Location: The timer is located inside the hopper housing just behind the left solenoid.Test Procedure:1. D

Strany 42

47SERVICE (Cont.)Timer (Model LPG-2E)Timer (Models LPG, FPG)P1748FIG. 49 TIMERLocation: The timer is located inside the rear access panel. Adjustment

Strany 43

48SERVICE (Cont.)Location: The timer is located on the timer bracket in the grinder base. The bracket can be removed by loosening the two 8-32 screws

Strany 44

49SERVICE (Cont.)DISPENSE TIME (Seconds)DISPLAYIncreaseDecreaseReadout will be displayed for 5 minutes.Timer can only be adjustedwhile readout is disp

Strany 45

541545 111711Figure 1Step 1 - Remove & discard tape holding funnel arm in place. (Figure 1)Step 2 - Remove & discard two silicon tubes between

Strany 46

50SERVICE (Cont.)Control Board (Model MHG)Location:The control board is located on the component mounting bracket mounted to the grinder base inside t

Strany 47

51SERVICE (Cont.)Control Board (Models FPG-2 & G9-2 DBC)Location:The control board is located inside the hopper housing behind the membrane switch

Strany 48

52SERVICE (Cont.)Membrane Switches (Model MHG only)Location:The membrane switch is located on the front of the hopper housing.Test Procedure:1. Press

Strany 49

53PERSONAL INJURYHAZARD.KEEP FINGERS ANDFOREIGN OBJECTSOUT OF HOPPER OR CHUTE OPENING.CAUTIONSERVICE (Cont.)Membrane Switches (Models FPG-2 & G9-2

Strany 50

54SERVICE (Cont.)EMI Filter (Models FPG & FPG-2)FIG 60 EMI FILTERFIG 61 EMI FILTER TERMINALSLocation: The EMI Filter is located inside the rear c

Strany 51

55SERVICE (Cont.)Funnel Sensing Coil (Models MHG & G9-2 DBC)Location:The funnel sensing coil is located inside of the coil cover.Test Procedure:1.

Strany 52

56SERVICE (Cont.)Memory Clock Board (Model MHG)Location:The memory clock board is located on the component mounting bracket mounted to the grinder bas

Strany 53

57Display Board (Model MHG)Location: The display board is located inside the hopper housing behind the membrane switch.Test Procedure:1. Press and h

Strany 54

58TRIAC MAP for MHG MOV1 controls Transformer @ J5-4,5,6 TH1 & MOV2 controls Left Gate @ J5-3 TH2 & MOV3 controls Relay

Strany 55

59TRIAC MAP for FPG-2 DBC and G9-2 DBC TH1 & MOV1 controls Left Gate @ J1-1 TH2 & MOV2 controls Relay @ J1-2 TH3 & MOV

Strany 56

6Model G9-2Off/On/Start SwitchOFF - (upper position) Switching to this position stops all operation of the grinder.ON - (middle position) The switch w

Strany 57

60SCHEMATIC WIRING DIAGRAM G9-2 DBC, G9-2T DBC W/SMART FUNNEL™ N WHI BLK L1 LEFT GATE LIMIT THERMOSTAT LIMIT THERMOSTAT SOL SOL WHI/ORA WHI/GRN WHI/YE

Strany 58 - TRIAC MAP for MHG

61SCHEMATIC WIRING DIAGRAM G9-2 DBC, G9-2T DBC W/SMART FUNNEL™ N WHI BLK L1 LEFT GATE LIMIT THERMOSTAT LIMIT THERMOSTAT SOL SOL WHI/ORA WHI/GRN WHI/YE

Strany 59

62SCHEMATIC WIRING DIAGRAM G9-2TB DBC W/SMART FUNNEL™ N WHI BLK L1 LEFT GATE LIMIT THERMOSTAT LIMIT THERMOSTAT SOL SOL WHI/ORA WHI/GRN WHI/YEL BLK WHI

Strany 60 - SCHEMATIC WIRING DIAGRAM

63SCHEMATIC WIRING DIAGRAM MHG N BLK WHI L1 RIGHT GATE LEFT HOPPER SENSOR LIMIT THERMOSTAT LIMIT THERMOSTAT WHI/YEL WHI/YEL WHI/GRN WHI/ORN WHI/ORN YE

Strany 61

64WIRING DIAGRAMS1 5 10 16J194J61J1251J15198STATICSHIELDSWITCH UNIT ASSYRIGHT HOPPER COILLEFT HOPPER COILFUNNEL COILT1LOADLINEVIOVIOORGORGYELYELK1RIGH

Strany 62 - G9-2TB DBC W/SMART FUNNEL™

6527103.0000D 04/07 ©1996BUNN-O-MATIC CORPORATIONSCHEMATIC WIRING DIAGRAMLPG-2E, LPGB-2ENL1BLKREDWHI100 VOLTS AC120 VOLTS AC2 WIRESINGLE PHASE60 H

Strany 63 - SCHEMATIC WIRING DIAGRAM MHG

66WIRING DIAGRAMS41545 122209

Strany 64 - MHG with WD CBA

67BLKWHIREDRED10529.0000C 3/92 © 1990BUNN-O-MATIC CORPORATIONSCHEMATIC WIRING DIAGRAMLPG & LPG2NL1BLKP1234561REDWHI/BLKBLKWHI/BLUWHI/BRNWHIG

Strany 65 - WIRING DIAGRAMS

68BLKWHIREDRED10529.0002E 8/01 © 1990BUNN-O-MATIC CORPORATIONSCHEMATIC WIRING DIAGRAMLPG-AL2L1BLKP1234561REDWHI/BLKBLKWHI/BLUWHI/BRNWHIGRNREDWHI/B

Strany 66

69BLKWHIREDRED10529.0003E 10/98 © 1998 BUNN-O-MATIC CORPORATIONSCHEMATIC WIRING DIAGRAMLPG W/CapacitorL1P123456112REDWHI/BLKBLKWHI/BLUWHI/BRNWHI

Strany 67 - LPG & LPG2

7URNOFFSTARTONCARAFEP1300Batch Selector Switch (Optional) URN - Switching to this position allows the correct amount of beans to be dispensed when gr

Strany 68

70BLKWHIREDRED10529.0001D 10/98 © 1990BUNN-O-MATIC CORPORATIONSCHEMATIC WIRING DIAGRAMLPG-BNL1BLKP1234561REDWHI/BLKBLKWHI/BLUWHI/BRNWHIGRNREDWHI/B

Strany 69 - LPG W/Capacitor

71WHI/VIOWHI/VIOWHI/BLUWHI/ORA1 or AGRN or GRN/YEL230V GRN/YELL1NSW1BLK WHI/REDSW2K0 or BML1 L2100 VOLT AC120 VOLT AC230 VOLT AC240 VOLT AC 2 WIRE +

Strany 70

7210173-0000F 4/91 © 1987 BUNN-O-MATIC CORPORATIONWHI/GRNBLKK1WHI/BLUML2L1120 VOLTS AC2 WIRESINGLE PHASE60 HZL1 NGREENK1 N.O.SCHEMATIC WIRING DIA

Strany 71

7310187-0000C 02/08© 1987 BUNN-O-MATIC CORPORATIONWHI/GRNBLKK1WHI/BLUML2L1230 VOLTS AC2 WIRE + GNDSINGLE PHASE50 HZL1 L2GREENK1 N.O.SCHEMATIC WIRI

Strany 72 - G9-URN/CARAFE

744 3 WHI/GRN 1 BLK WHI/BLU L2 L1 120 VOLTS AC2 WIRESINGLE PHASE60 HZ10388-0000B 12/88 © 1988 BUNN-O-MATIC CORPORATION L1 N GREEN K1 N.O. SCHEMATI

Strany 73

75BLUVIOYELGRYTANORARED/BLKWHIWHI/GRNWHI/ORAWHI/YELRED/BLKBLKWHI/REDWHI/BLUML2L1WHI/BLUWHI/BLKYEL230 VOLTS AC2 WIRESINGLE PHASE50 HZ10768.0000E 05/03

Strany 74

76WIRING DIAGRAMS41545 122209

Strany 75

77WIRING DIAGRAMSBLKWHIREDRED36781.0000A 04/04 ©2004BUNN-O-MATIC CORPORATIONSCHEMATIC WIRING DIAGRAMFPGNL1REDWHI/BLKBLKWHI/BLUWHI/BRNWHIREDWHI/BL

Strany 76

78WIRING DIAGRAMSSCHEMATIC WIRING DIAGRAMFPG-2 DBC, FPGB-2 DBCNWHIWHI/BLKBLKL1LEFT GATELIMIT THERMOSTATLIMIT THERMOSTATSOLSOLWHI/ORAWHI/GRNWHI/YELREDW

Strany 77

79WIRING DIAGRAMSNL1LEFTGATELIMITTHERMOSTATLIMITTHERMOSTATSOLWHI/ORAWHI/ORAWHI/GRNWHI/YELWHI/YELREDWHIWHIWHIWHIWHI/BLKWHIWHIWHIWHIGRN GRNWHIWHIJ1-6J1-

Strany 78 - FPG-2 DBC, FPGB-2 DBC

8Model G9-2T DBCGrind Pad (a)Pressing initiates a timed grind cycle.Stop Pad (b)Pressing ends the operation of the grinder.® PAD (c)Pressing the ® pad

Strany 79 - FPG-2A DBC

9OPERATING CONTROLS (Continued)P2947P2947Model FPGOff/On/Start Switch OFF - (upper position) Switching to this position stops all operation of the gr