Bunn WDG-2 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Příslušenství pro výrobu kávy Bunn WDG-2. Bunn WDG-2 User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 28
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
BUNN
®
DG-2
WDG-2
INSTALLATION & OPERATING MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
10854.0000 3/00 ©1995 Bunn-O-Matic Corporation
02328.0000(4)
Zobrazit stránku 0
1 2 3 4 5 6 ... 27 28

Shrnutí obsahu

Strany 1 - BUNN-O-MATIC CORPORATION

BUNN®DG-2WDG-2INSTALLATION & OPERATING MANUALBUNN-O-MATIC CORPORATIONPOST OFFICE BOX 3227SPRINGFIELD, ILLINOIS 62708-3227PHONE: (217) 529-6601

Strany 2 - 10854 030300

10Place funnel with filter into rails, press (Func) button to advance to FunctionOne.1. When entering this function, load sensor is tared. To gain acc

Strany 3 - USER NOTICES

11ProblemGrinder will not start.Remedy(A) Plug-in the grinder.(B) Check the voltage at the walloutlet with a voltmeter. It mustbe 120 volts ac.(A) Mo

Strany 4 - OPERATING CONTROLS

12TROUBLESHOOTING (cont.)Problem Probable Cause RemedyGrinder will not start. (cont.)Grinder starts, but will not dispense fromeither hopper.Timer wil

Strany 5 - WDG-2 INITIAL SET-UP

13TROUBLESHOOTING (cont.)ProblemWDG-2 DIGITAL DISPLAY CONTROL FAULT CODESNOTE: If the grinder stops or fails to start, the green L.E.D. should be flas

Strany 6 - 01384.0000

14SERVICEThis section provides procedures for testing andreplacing various major components used in thisgrinder should service become necessary. Refe

Strany 7

15SERVICE (cont.) The hopper is attached with ten #8-32 x .25” slot-ted head locking screws. Remove hopper by liftingup and swing out the rear of the

Strany 8 - CLEANING

16SERVICE (cont.)Hopper Selector Switch (cont.)Test Procedure:1. Disconnect grinder from the power supply.2. Remove all wires from the switch terminal

Strany 9

17SERVICE (cont.)Motor (cont.)Test Procedure:1. Disconnect grinder from the power supply.2. Remove upper front inspection panel.3. Remove the two 1/4&

Strany 10 - Coffee Weight/Timer Settings

18SERVICE (cont.)Motor (cont.)Removal and Replacement - GRIND CHAMBERH G D C

Strany 11 - TROUBLESHOOTING

19SERVICE (cont.)Timer - DG-2 (cont.)Test Procedure:1. Disconnect grinder from the power source.2. Slide timer with wires connected from housing.3. Pl

Strany 12 - TROUBLESHOOTING (cont.)

2CONTENTSIntroduction ... 2Warranty ...

Strany 13

20J412345678J167891012345BLK TO FUSE HOLDERWHI TO POWER CORDVIO TO SELECTOR SWITCHORA TO OFF/ON/START SWITCHORA TO OFF/ON/START SWITCHRED TO OFF/ON S

Strany 14 - Troubleshooting

21Grinders with One or Two Brewer Optional Interface1. Set the brewer selector switch on one thirdbatch with grinder "OFF/ON/START" switch i

Strany 15 - SERVICE (cont.)

22SERVICE (cont.)FanUse only on a properly protected circuitcapable of the rated load.Electrically ground the chassis.Follow national/local electrical

Strany 16

23L.E.D The L.E.D is located on the front of the grinderjust above hopper selector switch.Test Procedure:1. Unplug the grinder.2. Remove the wire nuts

Strany 17

24SERVICE (cont.)Weigh Control Assembly - WDG-2 (cont.)00718.000001593.000012345687P9411. Front Inspection Panel2. Weigh Control Board and Mounting Br

Strany 18

25SERVICE (cont.)Weigh Control Assembly - WDG-2 (cont.)Removal and Replacement1. Disconnect grinder from the power source.2. Remove the four #6-32 tru

Strany 19

26120 VOLTS AC2 WIRESINGLE PHASE60 HZREDJ1-1J1-10YELGRNTANGRYTANGRYBLKPNKJ4-8J4-1BLKWHIVIOWHIORAORAGRNBREWER INTERFACE CONNECTOR4321GRYTANPNK(OPTIONAL

Strany 20

27120 VOLTS AC2 WIRESINGLE PHASE60 HZREDYELGRNTANGRYTANGRYBLKPNKBLKWHIVIOWHIORAORAGRNL110 AMPNSELECTOR SWGRYORAWHI/BLUPNKPNKOFF/ONSTART SWYEL(OPTIONAL

Strany 22

3#20545.0000USER NOTICESCarefully read and follow all notices on the grinder and in this manual. They were written for your protection. All notices o

Strany 23 - 00718.0000

4ELECTRICAL REQUIREMENTSThis grinder has an attached cordset and requires 2-wire, grounded service rated 120 volts ac, 15 amp,single phase, 60 Hz.OPER

Strany 24

5DISPENSE TIME (Seconds)DISPLAYIncrease DecreaseReadout will be displayed for 5 minutes.Timer can only be adjustedwhile readout is displayed.+WARNINGH

Strany 25

6SPECIAL SET-UP FOR FLAVORED COFFEE BEANS1. WARNING - Unplug grinder before removal ofany panel.2. Select the hopper to be used for flavored coffeebea

Strany 27

8COFFEE GRINDING1. Select (either left or right hopper) with selector switch and visually inspect the desired hopper for an amplesupply of whole bean

Strany 28

9ADJUSTMENTSThe grind can be set from fine to very coarse. The grind may be adjusted for use in most commercial coffeebrewers. The following procedu

Komentáře k této Příručce

Žádné komentáře